HHP-V main features

 

HHP-VU

HHP-VW

The HHP-VU model is appropriate for operation at a temperature range of 1.5 - 350 K in magnetic fields up to 5 T. This type of probe features micro size active area and therefore, the device can be used as a scanning Hall probe for superconductor field mapping with enhanced accuracy. Its small overall dimensions make it ideally suited for space-limited applications. The dimensions of the active area are 50 x 50 microns and the overall dimensions are 5 x 4 x 0.9 mm. This probe is partially protected by a resin enclosure, but the electrical system remains uncovered. This construction allows to decrease the distance between the surface of the active area and the probe's surface to 150 microns.

HHP-VP

HHP-VP

The HHP-VP model characterizes transverse mounting construction with the same electrical specifications as the type HHP-VW. The active area center of this packaged sensor is properly marked by a cross, located with accuracy better then ± 0.05 mm. The overall dimensions are 7 x 5 x 1 mm. The model HHP-VP is a probe covered by special synthetic resin in transverse modification and its electrical system is parallel to the undersurface with high accuracy.

HHP-VA

HHP-VA

The HHP-VA model features axial mounting construction with the same electrical specifications as the model HHP-VW. A cross, located with accuracy better than ± 0.05 mm, properly marks the active area center of the packaged sensor. The overall diameter is 7 mm. The HHP-VA model is a probe covered by cryogenic synthetic resin in axial modification and its electrical system is parallel to the front wall of the cover with the highest precision.

HHP-VFO

HHP-VFO

The HHP-VFO model is similar to the HHP-VF model. This Hall probe is partially protected by a resin enclosure, but the electrical system remains uncovered. This construction allows decreasing the distance between the surface of the active area and the probe's surface to 120 microns. Overall diameter is 7 mm.

HHP-VC

HHP-VC

The model HHP-VC is developed for operation at a temperature range of 1.5 - 350 K in magnetic fields up to 5 T. Position of active area is shifted to the left (right) corner with the distance 250 microns from the corner edges. The probe is designed for high resolution mapping of the magnetic field, using an XY microstage-positioning device. Dimensions of the active area are 50 x 50 microns and the overall dimensions are 5 x 4 x 0.7 mm. The HHP-VC model is a probe with specially passivated uncovered semiconductor surface.